SFM with AE2 and Mekanism
What SFM 4.34 really knows about AE2 and Mekanism, powering an ME network from SFM, the ME Interface as SFM's way in and out of the network, driving AE2 inscribers, and running Mekanism machines by side with chemicals.
Applies to: ATM-10 8.6 · All the Mons 2.2.0 · ATM-11 0.16.0-beta
Versions: SFM 4.34.0 in all three packs, AE2 19.2.19 (ATM-10), 19.2.20 (All the Mons) and 26.1.13-beta (ATM-11), Mekanism 10.7.19 (not in ATM-11) measured · SFM source · issues
SFM reaches blocks through the standard item, fluid, energy and Mekanism chemical access, so it works with AE2 and Mekanism without special help. It does have a little special code for both, and some of it is switched off in 4.34.0, which changes what you’ll see in game. Read from SFM’s source (MPL-2.0) at the 1.21.1 tag, and from AE2’s and Mekanism’s. The language itself is on The SFM language. read
What SFM’s special code does, and doesn’t#
| Code in SFM 4.34.0 | State |
|---|---|
| AE2 Energy Acceptor fix, so SFM can push FE into it | on when AE2 is loaded |
| AE2 ME Interface seen as the whole network | written, but switched off (“will reintroduce it later once I figure out the performance characteristics”) |
Mekanism chemicals (chemical::, and the gas::, slurry::, pigment::, infusion:: aliases) | on |
| Mekanism energy in Joules | off; use fe:: |
| Warning for a Mekanism line with no side, or one that disagrees with the side config | written, but switched off |
| Inspector that writes sided lines from a Mekanism machine’s side config | written, but switched off |
SFM and AE2#
Powering an ME network#
AE2’s Energy Acceptor holds no buffer and reports a capacity of zero, which on its own would stop SFM from moving FE into it. SFM works around that (#322), and its own test moves FE from a Mekanism energy cube into an acceptor: read
name "Power the ME network"
every tick do
input fe:: from cube bottom side
output fe:: to acceptor top side
end
A trigger that moves only fe:: may run every tick. Remember AE2 counts
2 FE per AE. read
The ME Interface: SFM’s way in and out#
With its whole-network view switched off, SFM sees an ME Interface the way every mod does: its 9 slots. How the interface treats those slots makes it a two-way door: read
- Into the network: a slot with nothing set accepts anything, and the interface
passes whatever lands there on into network storage.
output to interfaceis a way to put SFM’s items into the ME system. - Out of the network: set a slot to an item, and the interface keeps it stocked
from the network.
input from interfacethen takes from that stock.
The same holds for fluids, and, with Applied Mekanistics, for Mekanism chemicals, since it gives interfaces a chemical slot too. estimate
When SFM beats AE2’s buses: one Factory Manager drives any number of machines
by label, with each, retain and slot numbers, and it costs no channels. A bus
handles one face and takes a channel. Let AE2 store and craft, and let SFM do the
fiddly feeding. estimate
Worked example: AE2 inscribers#
SFM’s own tests drive a full processor line. An inscriber shows all four of its slots on every face (unless it’s set to separate sides): read
| Slot | Holds | Automation can |
|---|---|---|
| 0 | top plate (a press, or a printed circuit) | insert while idle; not take out |
| 1 | bottom plate (printed silicon) | insert while idle; not take out |
| 2 | middle input | insert while idle; not take out |
| 3 | output | always take out; not insert |
Put a press in slot 0 of each printing inscriber by hand. Label them logic,
engineering, calculation and silicon (one inscriber or several each), the
assembly inscribers assembly, and two chests materials and results:
estimate
name "Processors"
every 20 ticks do
input from materials
output retain 2 gold_ingot to each logic slots 2
output retain 2 diamond to each engineering slots 2
output retain 2 certus_quartz_crystal to each calculation slots 2
output retain 2 silicon to each silicon slots 2
output retain 2 redstone to each assembly slots 2
output retain 2 printed_silicon to each assembly slots 1
output retain 2 printed_logic_processor, retain 2 printed_engineering_processor, retain 2 printed_calculation_processor to each assembly slots 0
forget
input from logic, engineering, calculation, silicon
output to materials
forget
input from assembly
output to results
end
The printed circuits go back to materials, so the first block feeds them on to the
assembly inscribers. Only the output slot can be taken from, so the two input
lines collect finished items and nothing else. An assembly inscriber takes whichever
printed circuit arrives first, so give each processor type its own inscriber if
you want one kind only. estimate
SFM and Mekanism#
Always name the side#
Mekanism answers by each face’s side configuration. A line with no side can read a Mekanism machine but can’t insert or extract, so it does nothing, and in 4.34.0 SFM doesn’t warn you. read Match each line to the face’s configured role:
- a face set to output (or input/output):
input ... from machine <face> side; - a face set to input:
output ... to machine <face> side.
Faces are top, bottom, north, south, east, west, or relative left,
right, front, back.
Energy#
Use fe:: for Mekanism power; SFM’s Joule type is switched off. Mekanism counts
2.5 J per FE, so an fe:: line of 1,000 moves 2,500 J. read
Worked example: chemicals for the ore chain#
SFM is a tidy way to keep the chemical inputs of a 5× chain topped up, the part that
shouldn’t be encoded into AE2 patterns (see
Mekanism and AE2).
Label the tanks or plants acid, hcl and oxygen, and the machines
dissolvers, injectors and purifiers; each machine’s top face is set to its
chemical input, each plant’s bottom face to output: estimate
name "Ore chain chemicals"
every 20 ticks do
input chemical::sulfuric_acid from acid bottom side
output retain 4000 chemical::sulfuric_acid to each dissolvers top side
forget
input chemical::hydrogen_chloride from hcl bottom side
output retain 4000 chemical::hydrogen_chloride to each injectors top side
forget
input chemical::oxygen from oxygen bottom side
output retain 4000 chemical::oxygen to each purifiers top side
end
Chemical amounts are in millibuckets. retain 4000 ... to each keeps every
machine’s chemical tank at up to 4,000 mB between runs. At base speed a machine
uses about 1 mB a tick, so that’s plenty. Speed upgrades change it a lot at the
packs’ upgrade multiplier: eight speed upgrades and no chemical upgrades use about
256 mB a tick, over 5,000 mB between runs. Add chemical upgrades, or raise the
retain, if a machine runs dry. estimate
ATM-11#
ATM-11 has SFM and AE2 but no Mekanism. measured It runs SFM’s separate 26.1 build, which this page didn’t read, so which special code is on or off there may differ. The ME Interface behaviour comes from AE2, whose interface works the same way in 26.1. estimate